TE Distributor
Best Price Now
Relays, Contactors & Switches (Relays)
Manufacturer / Brand: TE
Desc.: Axicom MT2 Relay, Signal Relays, 250VAC Contact Voltage Rating, 220VDC Contact Voltage Rating, 150mW Signal Relay Coil Power Rating (DC)
Alias (Internal Part Number): AMP-1-1462000-8
Quantity Available: Over 484800 Pieces
Our Email: sales@buy-te.com (Price quote by email)
Detailed Description for C93404:
-
Contact Voltage Rating (VAC): 250
-
Contact Voltage Rating (VDC): 220
-
Signal Relay Coil Power Rating (DC) (mW): 150
-
Isolation (HF Parameter) : -14.2dB @ 900MHz, -31.8dB @ 100MHz
-
Insertion Loss (HF Parameter) : -.02dB @ 100MHz, -.97dB @ 900MHz
C93404 Parameters
- Manufacturer Part Number : C93404
- Manufacturer : TE
- Description : Axicom MT2 Relay, Signal Relays, 250VAC Contact Voltage Rating, 220VDC Contact Voltage Rating, 150mW Signal Relay Coil Power Rating (DC)
- Series: Axicom
- TE Internal Part Code: 1-1462000-8
- Internal Description: C93404=MT RELAY 150MW 48V
- Our Price : Contact by email
- Function : -
- Status : Active
- ROHS Status : Rohs Compliant
- Package Type : -
- Standard Packing Type : Reel / Tray / Box
- Standard Packing Quantity : -
- Working Temperature : -
- Other Part Number : TE-C93404
- Shipping methods : DHL FEDEX UPS TNT
- Delivery Time : Ship within 1 day.
- Manufacturer Production time : 6-8 weeks (Normally have stocks)
- Weight : -
- Other category: -
Request Quotation for C93404
Best Price for C93404
Contact us to check the best price and real time inventory quantity for C93404. If you need any more information about C93404, you can also send us by email. Our email is sales@buy-te.com
C93404 Technical Documents (Datasheet and Drawing Files)
Product Description
Signal relay with low coil power for saving energy (200mW), switching and continous current 3A, Dimensions 20x10x11mm, 2 form C contacts
View All AXICOM MT2 HIGH SENSITIVE (7)
Product Drawings
- C93404=MT RELAY 150MW 48V C93404=MT RELAY 150MW 48V English
CAD Files
- 3D PDF 3D_CVM_CVM_1-1462000-8_C.pdf 3D
- Customer View Model ENG_CVM_CVM_1-1462000-8_C.2d_dxf.zip English
- ENG_CVM_CVM_1-1462000-8_C.3d_igs.zip English
- ENG_CVM_CVM_1-1462000-8_C.3d_stp.zip English
Datasheets & Catalog Pages
- Transportation, Storage, Handling, Assembly and Testing of AXICOM THT Relays ENG_CS_Axicom_AppNote_1_0513_1_THT_Relays-r.pdf English
- Industrial Relays Quick Reference Guide ENG_DS_1-1773969-4_2002.pdf English
Product Specifications
- Product Specification ENG_SS_108-98006_1017.pdf English
- Definitions Relays ENG_SS_Definitions_Relays_0518.pdf English
Additional Description for C93404
Product Description
Signal relay with low coil power for saving energy (200mW), switching and continous current 3A, Dimensions 20x10x11mm, 2 form C contacts
View All AXICOM MT2 HIGH SENSITIVE (7)
Please review product documents or contact us for the latest agency approval information.
Please Note: Use the Product Drawing for all design activity.
Product Type Features
-
Product Type : Relay
-
Relay Style : MT2 Relay
-
Relay Type : MT2 Relay
Electrical Characteristics
-
Coil Special Features : High Sensitive Version
-
Contact Switching Load (Min) : 10mA @ .02V
-
Contact Limiting Breaking Current (A): 2
-
Contact Voltage Rating (VAC): 250
-
Contact Voltage Rating (VDC): 220
-
Signal Relay Coil Power Rating (DC) (mW): 150
-
Signal Relay Coil Voltage Rating (VDC): 48
-
Signal Relay Contact Switching Voltage (Max) (VAC): 250
-
Signal Relay Contact Switching Voltage (Max) (VDC): 220
-
Signal Relay Coil Magnetic System : Monostable, DC
-
Coil Type : Monostable
-
Contact Limiting Continuous Current (A): 2
-
Coil Resistance (Ω): 15468
-
Contact Limiting Making Current (A): 2
-
Insulation Initial Resistance (MΩ): 1000
-
Power Consumption (mW): 150
-
Insulation Initial Dielectric Between Adjacent Contacts (Vrms): 750
-
Voltage Standing Wave Ration (HF Parameter) : 1.03 @ 100MHz, 1.31 @ 900MHz
-
Insulation Initial Dielectric Between Coil/Contact Class : 1000 V – 1500 VA
-
Insulation Initial Dielectric Between Contacts and Coil (Vrms): 1050
-
Contact Limiting Short-Time Current (A): 2
-
Insulation Initial Dielectric Between Open Contacts (Vrms): 750
-
Actuating System : DC
-
Coil Power Rating Class : 100 – 150 mW
Signal Characteristics
-
Isolation (HF Parameter) : -14.2dB @ 900MHz, -31.8dB @ 100MHz
-
Insertion Loss (HF Parameter) : -.02dB @ 100MHz, -.97dB @ 900MHz
Body Features
-
Weight : 5 g [ .1764 oz ]
Contact Features
-
Signal Relay Terminal Type : PCB-THT
-
Signal Relay Contact Current Rating (A): 2
-
Signal Relay Contact Arrangement : 2 Form C (2 CO)
-
Contact Material : Nickel-Titanium
-
Contact Number of Poles : 2
-
Contact Special Features : Bifurcated/Twin Contacts
-
Contact Current Class : 0 – 2 A
-
Contact Plating Material : Gold
Termination Features
-
Termination Type : Through Hole
Mechanical Attachment
-
Signal Relay Mounting Type : Printed Circuit Board
Dimensions
-
Dimensions (L x W x H) (Approximate) (mm): 20.2 x 10 x 10.8
-
Length : 20.2 mm [ .795 in ]
-
Height Class (Mechanical) : 10 – 11 mm
-
Length Class (Mechanical) : 20 – 25 mm
-
Height : 10.8 mm [ .425 in ]
-
Width : 10 mm [ .394 in ]
-
Width Class (Mechanical) : 8 – 10 mm
Usage Conditions
-
Operating Temperature Range (°C): -55 – 85
-
Environmental Category of Protection : RTIII
-
Environmental Ambient Temperature Class : 70 – 85°C
-
Environmental Ambient Temperature (Max) : 85 °C [ 185 °F ]
Operation/Application
-
Performance Type : Standard
Packaging Features
-
Packaging Method : Box & Tube
We also sell the below TE Products
Email: sales@buy-te.com
Stocking Distributor for All series Connectors - RELAY - Passive Components